WhatsApp ไธญๆ–‡ ะ ัƒััะบะธะน
F5/F6 Panel Medium Filter - Air Filtration

F5/F6 Panel Medium Filter

Rigid panel medium efficiency filter

AirflowF5/F6 (MERV 10-13)
Pressure RangeInitial resistance <50 Pa
Motor PowerN/A
MaterialMicro-glass fiber / Aluminum frame
CertificationsISO9001
Share:
โœ“ Direct Manufacturer โœ“ 30+ Years Experience โœ“ 50+ Countries Served โœ“ Full Customization

Product Overview

F5/F6 rigid panel medium efficiency filter for AHU secondary-stage filtration. Rigid construction with mini-pleat media for high airflow and low pressure drop.

Key Features

  • F5/F6 / MERV 10-13 rated
  • Rigid mini-pleat construction
  • High airflow capacity
  • Low pressure drop

Procurement & Commercial Terms

Minimum Order Quantity1 unit (made to order)
Production Lead Time15โ€“30 working days after deposit confirmation
Delivery TermsFOB Qingdao / EXW Dezhou, China
Payment TermsT/T 30% deposit, 70% before shipment; L/C at sight accepted
Warranty18 months from shipment
OEM / ODMAvailable โ€” custom airflow, pressure, material & voltage
CertificationsISO9001

Why specify Keruite: With an airflow range of F5/F6 (MERV 10-13) and pressure up to Initial resistance <50 Pa, the F5/F6 Panel Medium Filter is engineered for demanding AHU secondary filtration duties and built from Micro-glass fiber / Aluminum frame for long service life. As a direct manufacturer since 1995 with an 80,000 mยฒ production base and equipment exported to 50+ countries, we supply the F5/F6 Panel Medium Filter with full performance test reports, general arrangement drawings, and factory-audit support. Request a quotation →

Key Features

  • โœ“ F5/F6
  • โœ“ Rigid panel
  • โœ“ High airflow
  • โœ“ Low pressure drop

Applications

  • โ— AHU secondary filtration
  • โ— Commercial HVAC
  • โ— Industrial ventilation

Compliance & Certifications

โœ…
CCC
China Compulsory Cert.
โœ…
CE
EU Conformity Mark
โœ…
ISO 9001
Quality Management
โœ…
ATEX
Explosion-Proof (Ex d)

Note: Specific certifications available depend on product type and market. For ATEX/Ex d applications, please specify gas group, temperature class, and zone classification in your inquiry. Full type test certificates and Declarations of Conformity are included with every Ex-rated unit.

Videos From Our Factory

Keruite Fan & Air Valve Workshop Introduction - F5/F6 Panel Medium Filter

Keruite Fan & Air Valve Workshop Introduction

Welcome to the Fan and Air Valve production workshop at Keruite Air Conditioning Group. This dedicated facilit...

Fresh Air Sand Removal Units โ€“ Keruite Product Showcase - F5/F6 Panel Medium Filter

Fresh Air Sand Removal Units โ€“ Keruite Product Showcase

Keruite Air Conditioning Group presents our fresh air sand removal units, engineered specifically for environm...

Industrial Centrifugal Fans โ€“ Technical Knowledge Sharing - F5/F6 Panel Medium Filter

Industrial Centrifugal Fans โ€“ Technical Knowledge Sharing

Industrial centrifugal fans are fluid machinery that convert mechanical energy into gas pressure and kinetic e...

Performance Curve

Airflow (mยณ/h) Pressure (Pa) Max Speed Mid Speed Low Speed

Representative performance curves at different speeds. Contact us for detailed performance data specific to your required model and operating conditions.

Dimensions & Installation

Inlet Outlet Motor L (Length) H (Height) W (Width)

Schematic dimension diagram. Exact dimensions vary by model number. Request the technical datasheet for precise specifications.

Frequently Asked Questions

What is the airflow range of the F5/F6 Panel Medium Filter?

The F5/F6 Panel Medium Filter delivers an airflow range of F5/F6 (MERV 10-13). Contact us with your specific requirements for precise model selection.

What motor power options are available?

Motor power ranges from N/A. We offer standard IE2/IE3 efficiency motors and can customize voltage and frequency for your region (380V/50Hz, 460V/60Hz, etc.).

What materials are available for construction?

Standard construction materials include: Micro-glass fiber / Aluminum frame. Custom materials such as SS316L, FRP, or special coatings are available upon request for corrosive or high-temperature environments.

Do you provide customization for specific applications?

Yes. As a direct manufacturer with 30+ years of experience, Keruite offers full customization including airflow, pressure, material, voltage, motor brand, and special features (explosion-proof, high-temperature, corrosion-resistant). Send us your specifications via the inquiry form.

What certifications does this product have?

This product holds the following certifications: ISO9001. Full certification documents are available upon request.

What is the typical lead time for production?

Standard models typically have a 15-25 day production lead time. Custom or made-to-order units may require 30-45 days depending on specifications and quantity. Contact us for an accurate delivery estimate based on your order.

Selection Guide

Follow these steps to select the right F5/F6 Panel Medium Filter model for your application.

1

Determine Required Airflow

Calculate the total airflow needed for your space. The F5/F6 Panel Medium Filter covers F5/F6 (MERV 10-13). Consider room volume, air changes per hour (ACH), and ventilation standards (ASHRAE 62.1, EN 16798-1).

2

Calculate System Pressure

Account for duct resistance, filters, dampers, and fittings. The F5/F6 Panel Medium Filter handles pressure up to Initial resistance <50 Pa. Add 10-15% safety margin to your calculated total static pressure.

3

Select Motor Power

Available motor power: N/A. Choose IE3 high-efficiency motors for continuous operation. Ensure your power supply matches the rated voltage and frequency.

4

Choose Material & Coating

Standard: Micro-glass fiber / Aluminum frame. For corrosive environments, upgrade to SS316L or FRP. For high-temperature applications (>150ยฐC), request heat-resistant coating and Class H motor insulation.

5

Confirm Installation & Control

Verify mounting orientation, inlet/outlet dimensions, and control requirements (VFD, two-speed, or on/off). Download the installation manual or contact our engineering team for assistance.

7

Request a Quotation

Submit your specifications via the inquiry form. Include airflow, pressure, voltage, application, and quantity. Our engineers will review and provide a detailed quotation within 24 hours.

Request a Quote Request a Technical Proposal Download Catalog

Related Products

G4 Panel Pre-filter - related product by Keruite

G4 Panel Pre-filter

Washable G4 panel filter for coarse dust

View Details
F8 Bag-type Medium Filter - related product by Keruite

F8 Bag-type Medium Filter

High dust holding bag filter

View Details
V-bank HEPA Filter - related product by Keruite

V-bank HEPA Filter

Mini-pleat V-bank HEPA filter

View Details
Activated Carbon Filter - related product by Keruite

Activated Carbon Filter

Odor and gas removal carbon filter

View Details

Interested in F5/F6 Panel Medium Filter?

Send us your specifications โ€” airflow, pressure, voltage, and application โ€” for a tailored quotation within 24 hours.