WhatsApp ไธญๆ–‡ ะ ัƒััะบะธะน
Operating Theater Air Handling Unit - Hospital Purification

Operating Theater Air Handling Unit

Specialized AHU for operating theaters

Airflow3,000~15,000 m3/h
Pressure Range300~800 Pa
Motor Power2.2~18.5 kW
MaterialSS304 / Galvanized Steel
CertificationsISO9001;CE;CCC
Share:
โœ“ Direct Manufacturer โœ“ 30+ Years Experience โœ“ 50+ Countries Served โœ“ Full Customization

Product Overview

Specialized air handling unit for hospital operating theaters. Features multi-stage HEPA filtration, humidity control, and sterile air delivery with precise temperature accuracy.

Key Features

  • Multi-stage HEPA H14 filtration
  • Temperature accuracy +-0.5 C
  • Humidity control +-5%RH
  • Sterile air delivery
  • Redundant fan design

Procurement & Commercial Terms

Minimum Order Quantity1 unit (made to order)
Production Lead Time15โ€“30 working days after deposit confirmation
Delivery TermsFOB Qingdao / EXW Dezhou, China
Payment TermsT/T 30% deposit, 70% before shipment; L/C at sight accepted
Warranty18 months from shipment
OEM / ODMAvailable โ€” custom airflow, pressure, material & voltage
CertificationsISO9001, CE, CCC

Why specify Keruite: With an airflow range of 3,000~15,000 m3/h and pressure up to 300~800 Pa, the Operating Theater Air Handling Unit is engineered for demanding Operating theaters duties and built from SS304 / Galvanized Steel for long service life. As a direct manufacturer since 1995 with an 80,000 mยฒ production base and equipment exported to 50+ countries, we supply the Operating Theater Air Handling Unit with full performance test reports, general arrangement drawings, and factory-audit support. Request a quotation →

Key Features

  • โœ“ HEPA H14
  • โœ“ +-0.5 C accuracy
  • โœ“ Humidity control
  • โœ“ Sterile delivery
  • โœ“ Redundant fans

Applications

  • โ— Operating theaters
  • โ— ICU rooms
  • โ— Isolation wards
  • โ— Burn units

Compliance & Certifications

โœ…
CCC
China Compulsory Cert.
โœ…
CE
EU Conformity Mark
โœ…
ISO 9001
Quality Management
โœ…
ATEX
Explosion-Proof (Ex d)

Note: Specific certifications available depend on product type and market. For ATEX/Ex d applications, please specify gas group, temperature class, and zone classification in your inquiry. Full type test certificates and Declarations of Conformity are included with every Ex-rated unit.

Videos From Our Factory

Ceiling Mounted Jet Air Conditioning Units โ€“ Keruite Product Showcase - Operating Theater Air Handling Unit

Ceiling Mounted Jet Air Conditioning Units โ€“ Keruite Product Showcase

Keruite Air Conditioning Group presents our ceiling mounted jet air conditioning units, engineered specificall...

Keruite HVAC Product Showcase | Central Air Handling Units, Fan Coils, Rooftop AC & More - Operating Theater Air Handling Unit

Keruite HVAC Product Showcase | Central Air Handling Units, Fan Coils, Rooftop AC & More

Welcome to Keruite Air Conditioning Group's comprehensive product showcase. This video presents our complete H...

Ultra-Large FRP Industrial Centrifugal Fans โ€“ Keruite Product Introduction - Operating Theater Air Handling Unit

Ultra-Large FRP Industrial Centrifugal Fans โ€“ Keruite Product Introduction

Keruite Air Conditioning Group presents our ultra-large FRP (Fiberglass Reinforced Plastic) industrial centrif...

Performance Curve

Airflow (mยณ/h) Pressure (Pa) Max Speed Mid Speed Low Speed

Representative performance curves at different speeds. Contact us for detailed performance data specific to your required model and operating conditions.

Dimensions & Installation

Inlet Outlet Motor L (Length) H (Height) W (Width)

Schematic dimension diagram. Exact dimensions vary by model number. Request the technical datasheet for precise specifications.

Frequently Asked Questions

What is the airflow range of the Operating Theater Air Handling Unit?

The Operating Theater Air Handling Unit delivers an airflow range of 3,000~15,000 m3/h. Contact us with your specific requirements for precise model selection.

What motor power options are available?

Motor power ranges from 2.2~18.5 kW. We offer standard IE2/IE3 efficiency motors and can customize voltage and frequency for your region (380V/50Hz, 460V/60Hz, etc.).

What materials are available for construction?

Standard construction materials include: SS304 / Galvanized Steel. Custom materials such as SS316L, FRP, or special coatings are available upon request for corrosive or high-temperature environments.

Do you provide customization for specific applications?

Yes. As a direct manufacturer with 30+ years of experience, Keruite offers full customization including airflow, pressure, material, voltage, motor brand, and special features (explosion-proof, high-temperature, corrosion-resistant). Send us your specifications via the inquiry form.

What certifications does this product have?

This product holds the following certifications: ISO9001;CE;CCC. Full certification documents are available upon request.

What is the typical lead time for production?

Standard models typically have a 15-25 day production lead time. Custom or made-to-order units may require 30-45 days depending on specifications and quantity. Contact us for an accurate delivery estimate based on your order.

Selection Guide

Follow these steps to select the right Operating Theater Air Handling Unit model for your application.

1

Determine Required Airflow

Calculate the total airflow needed for your space. The Operating Theater Air Handling Unit covers 3,000~15,000 m3/h. Consider room volume, air changes per hour (ACH), and ventilation standards (ASHRAE 62.1, EN 16798-1).

2

Calculate System Pressure

Account for duct resistance, filters, dampers, and fittings. The Operating Theater Air Handling Unit handles pressure up to 300~800 Pa. Add 10-15% safety margin to your calculated total static pressure.

3

Select Motor Power

Available motor power: 2.2~18.5 kW. Choose IE3 high-efficiency motors for continuous operation. Ensure your power supply matches the rated voltage and frequency.

4

Choose Material & Coating

Standard: SS304 / Galvanized Steel. For corrosive environments, upgrade to SS316L or FRP. For high-temperature applications (>150ยฐC), request heat-resistant coating and Class H motor insulation.

5

Confirm Installation & Control

Verify mounting orientation, inlet/outlet dimensions, and control requirements (VFD, two-speed, or on/off). Download the installation manual or contact our engineering team for assistance.

7

Request a Quotation

Submit your specifications via the inquiry form. Include airflow, pressure, voltage, application, and quantity. Our engineers will review and provide a detailed quotation within 24 hours.

Request a Quote Request a Technical Proposal Download Catalog

Related Products

EC Digital Energy-Saving Fan - related product by Keruite

EC Digital Energy-Saving Fan

EC motor-driven variable speed fan

View Details
Digital Energy-Saving Air Handling Unit - related product by Keruite

Digital Energy-Saving Air Handling Unit

Smart AHU with digital control for hospitals

View Details
EMH Distributed Power Module - related product by Keruite

EMH Distributed Power Module

Distributed intelligent power module for HVAC

View Details
Multi-Filter Fan Box - related product by Keruite

Multi-Filter Fan Box

Multi-stage filtration fan box for cleanrooms

View Details

Interested in Operating Theater Air Handling Unit?

Send us your specifications โ€” airflow, pressure, voltage, and application โ€” for a tailored quotation within 24 hours.