HLF Mixed Flow Fan Box
Cabinet mixed flow fan for dual-purpose ventilation
HLF Mixed Flow Fan Box
Cabinet mixed flow fan for dual-purpose ventilation
| Airflow | 2,000~50,000 m3/h |
|---|---|
| Pressure Range | 200~1,000 Pa |
| Motor Power | 0.55~30 kW |
| Material | Galvanized Steel |
| Certifications | CCC;ISO9001 |
Product Overview
HLF series cabinet mixed flow fan box for dual-purpose ventilation and fire exhaust. Combines the quiet operation of a cabinet fan with mixed flow performance.
Key Features
- Cabinet mixed flow design
- Sound-insulated housing
- Dual-purpose ventilation
- 280 C/30min fire rated
Procurement & Commercial Terms
| Minimum Order Quantity | 1 unit (made to order) |
|---|---|
| Production Lead Time | 15โ30 working days after deposit confirmation |
| Delivery Terms | FOB Qingdao / EXW Dezhou, China |
| Payment Terms | T/T 30% deposit, 70% before shipment; L/C at sight accepted |
| Warranty | 18 months from shipment |
| OEM / ODM | Available โ custom airflow, pressure, material & voltage |
| Certifications | CCC, ISO9001 |
Why specify Keruite: With an airflow range of 2,000~50,000 m3/h and pressure up to 200~1,000 Pa, the HLF Mixed Flow Fan Box is engineered for demanding Commercial buildings duties and built from Galvanized Steel for long service life. As a direct manufacturer since 1995 with an 80,000 mยฒ production base and equipment exported to 50+ countries, we supply the HLF Mixed Flow Fan Box with full performance test reports, general arrangement drawings, and factory-audit support. Request a quotation →
Key Features
- Cabinet design
- Sound-insulated
- Dual-purpose
- Fire rated
Applications
- Commercial buildings
- Hotels
- Hospitals
- Shopping malls
Industry Applications
This product is engineered for the following industry environments. Explore our dedicated solutions pages for more details:
Compliance & Certifications
Note: Specific certifications available depend on product type and market. For ATEX/Ex d applications, please specify gas group, temperature class, and zone classification in your inquiry. Full type test certificates and Declarations of Conformity are included with every Ex-rated unit.
Videos From Our Factory
Centrifugal Backward-Curved Fans โ Full Truckload Shipment in Progress
Behind the scenes at Keruite Air Conditioning Group: watch a full truckload of centrifugal backward-curved fan...
Keruite HVAC Product Showcase | Central Air Handling Units, Fan Coils, Rooftop AC & More
Welcome to Keruite Air Conditioning Group's comprehensive product showcase. This video presents our complete H...
Keruite Fan & Air Valve Workshop Introduction
Welcome to the Fan and Air Valve production workshop at Keruite Air Conditioning Group. This dedicated facilit...
Performance Curve
Representative performance curves at different speeds. Contact us for detailed performance data specific to your required model and operating conditions.
Dimensions & Installation
Schematic dimension diagram. Exact dimensions vary by model number. Request the technical datasheet for precise specifications.
Frequently Asked Questions
What is the airflow range of the HLF Mixed Flow Fan Box?
The HLF Mixed Flow Fan Box delivers an airflow range of 2,000~50,000 m3/h. Contact us with your specific requirements for precise model selection.
What motor power options are available?
Motor power ranges from 0.55~30 kW. We offer standard IE2/IE3 efficiency motors and can customize voltage and frequency for your region (380V/50Hz, 460V/60Hz, etc.).
What materials are available for construction?
Standard construction materials include: Galvanized Steel. Custom materials such as SS316L, FRP, or special coatings are available upon request for corrosive or high-temperature environments.
Do you provide customization for specific applications?
Yes. As a direct manufacturer with 30+ years of experience, Keruite offers full customization including airflow, pressure, material, voltage, motor brand, and special features (explosion-proof, high-temperature, corrosion-resistant). Send us your specifications via the inquiry form.
What certifications does this product have?
This product holds the following certifications: CCC;ISO9001. Full certification documents are available upon request.
What is the typical lead time for production?
Standard models typically have a 15-25 day production lead time. Custom or made-to-order units may require 30-45 days depending on specifications and quantity. Contact us for an accurate delivery estimate based on your order.
Selection Guide
Follow these steps to select the right HLF Mixed Flow Fan Box model for your application.
Determine Required Airflow
Calculate the total airflow needed for your space. The HLF Mixed Flow Fan Box covers 2,000~50,000 m3/h. Consider room volume, air changes per hour (ACH), and ventilation standards (ASHRAE 62.1, EN 16798-1).
Calculate System Pressure
Account for duct resistance, filters, dampers, and fittings. The HLF Mixed Flow Fan Box handles pressure up to 200~1,000 Pa. Add 10-15% safety margin to your calculated total static pressure.
Select Motor Power
Available motor power: 0.55~30 kW. Choose IE3 high-efficiency motors for continuous operation. Ensure your power supply matches the rated voltage and frequency.
Choose Material & Coating
Standard: Galvanized Steel. For corrosive environments, upgrade to SS316L or FRP. For high-temperature applications (>150ยฐC), request heat-resistant coating and Class H motor insulation.
Confirm Installation & Control
Verify mounting orientation, inlet/outlet dimensions, and control requirements (VFD, two-speed, or on/off). Download the installation manual or contact our engineering team for assistance.
Request a Quotation
Submit your specifications via the inquiry form. Include airflow, pressure, voltage, application, and quantity. Our engineers will review and provide a detailed quotation within 24 hours.
Download Resources
Related Products