WhatsApp ไธญๆ–‡ ะ ัƒััะบะธะน
GXF Diagonal Flow Fire Fan - Fire & Smoke Exhaust

GXF Diagonal Flow Fire Fan

Diagonal flow fan for fire smoke exhaust

Airflow2,000~50,000 m3/h
Pressure Range200~1,000 Pa
Motor Power0.55~45 kW
MaterialHeat-resistant Steel
CertificationsCCC;ISO9001
Share:
โœ“ Direct Manufacturer โœ“ 30+ Years Experience โœ“ 50+ Countries Served โœ“ Full Customization

Product Overview

GXF series diagonal flow fire exhaust fan for high-efficiency smoke extraction. Diagonal impeller design provides excellent pressure-airflow balance for fire safety systems.

Key Features

  • Diagonal flow impeller design
  • Balanced pressure and airflow
  • 280 C/30min fire rated
  • CCC certified

Procurement & Commercial Terms

Minimum Order Quantity1 unit (made to order)
Production Lead Time15โ€“30 working days after deposit confirmation
Delivery TermsFOB Qingdao / EXW Dezhou, China
Payment TermsT/T 30% deposit, 70% before shipment; L/C at sight accepted
Warranty18 months from shipment
OEM / ODMAvailable โ€” custom airflow, pressure, material & voltage
CertificationsCCC, ISO9001

Why specify Keruite: With an airflow range of 2,000~50,000 m3/h and pressure up to 200~1,000 Pa, the GXF Diagonal Flow Fire Fan is engineered for demanding Fire safety systems duties and built from Heat-resistant Steel for long service life. As a direct manufacturer since 1995 with an 80,000 mยฒ production base and equipment exported to 50+ countries, we supply the GXF Diagonal Flow Fire Fan with full performance test reports, general arrangement drawings, and factory-audit support. Request a quotation →

Key Features

  • โœ“ Diagonal flow
  • โœ“ Balanced performance
  • โœ“ Fire rated
  • โœ“ CCC certified

Applications

  • โ— Fire safety systems
  • โ— Tunnels
  • โ— Underground garages

Compliance & Certifications

โœ…
CCC
China Compulsory Cert.
โœ…
CE
EU Conformity Mark
โœ…
ISO 9001
Quality Management
โœ…
ATEX
Explosion-Proof (Ex d)

Note: Specific certifications available depend on product type and market. For ATEX/Ex d applications, please specify gas group, temperature class, and zone classification in your inquiry. Full type test certificates and Declarations of Conformity are included with every Ex-rated unit.

Videos From Our Factory

4-72 Industrial Centrifugal Fan โ€“ Keruite Product Introduction - GXF Diagonal Flow Fire Fan

4-72 Industrial Centrifugal Fan โ€“ Keruite Product Introduction

Keruite Air Conditioning Group presents our 4-72 series industrial centrifugal fans, one of the most widely us...

Industrial High-Pressure Centrifugal Fans โ€“ Factory Shipment in Progress - GXF Diagonal Flow Fire Fan

Industrial High-Pressure Centrifugal Fans โ€“ Factory Shipment in Progress

Behind the scenes at Keruite Air Conditioning Group: watch our industrial high-pressure centrifugal fans being...

External Rotor Air Conditioning Fans โ€“ Keruite Product Introduction - GXF Diagonal Flow Fire Fan

External Rotor Air Conditioning Fans โ€“ Keruite Product Introduction

Keruite Air Conditioning Group presents our external rotor air conditioning fans, featuring an innovative moto...

Performance Curve

Airflow (mยณ/h) Pressure (Pa) Max Speed Mid Speed Low Speed

Representative performance curves at different speeds. Contact us for detailed performance data specific to your required model and operating conditions.

Dimensions & Installation

Inlet Outlet Motor L (Length) H (Height) W (Width)

Schematic dimension diagram. Exact dimensions vary by model number. Request the technical datasheet for precise specifications.

Frequently Asked Questions

What is the airflow range of the GXF Diagonal Flow Fire Fan?

The GXF Diagonal Flow Fire Fan delivers an airflow range of 2,000~50,000 m3/h. Contact us with your specific requirements for precise model selection.

What motor power options are available?

Motor power ranges from 0.55~45 kW. We offer standard IE2/IE3 efficiency motors and can customize voltage and frequency for your region (380V/50Hz, 460V/60Hz, etc.).

What materials are available for construction?

Standard construction materials include: Heat-resistant Steel. Custom materials such as SS316L, FRP, or special coatings are available upon request for corrosive or high-temperature environments.

Do you provide customization for specific applications?

Yes. As a direct manufacturer with 30+ years of experience, Keruite offers full customization including airflow, pressure, material, voltage, motor brand, and special features (explosion-proof, high-temperature, corrosion-resistant). Send us your specifications via the inquiry form.

What certifications does this product have?

This product holds the following certifications: CCC;ISO9001. Full certification documents are available upon request.

What is the typical lead time for production?

Standard models typically have a 15-25 day production lead time. Custom or made-to-order units may require 30-45 days depending on specifications and quantity. Contact us for an accurate delivery estimate based on your order.

Selection Guide

Follow these steps to select the right GXF Diagonal Flow Fire Fan model for your application.

1

Determine Required Airflow

Calculate the total airflow needed for your space. The GXF Diagonal Flow Fire Fan covers 2,000~50,000 m3/h. Consider room volume, air changes per hour (ACH), and ventilation standards (ASHRAE 62.1, EN 16798-1).

2

Calculate System Pressure

Account for duct resistance, filters, dampers, and fittings. The GXF Diagonal Flow Fire Fan handles pressure up to 200~1,000 Pa. Add 10-15% safety margin to your calculated total static pressure.

3

Select Motor Power

Available motor power: 0.55~45 kW. Choose IE3 high-efficiency motors for continuous operation. Ensure your power supply matches the rated voltage and frequency.

4

Choose Material & Coating

Standard: Heat-resistant Steel. For corrosive environments, upgrade to SS316L or FRP. For high-temperature applications (>150ยฐC), request heat-resistant coating and Class H motor insulation.

5

Confirm Installation & Control

Verify mounting orientation, inlet/outlet dimensions, and control requirements (VFD, two-speed, or on/off). Download the installation manual or contact our engineering team for assistance.

7

Request a Quotation

Submit your specifications via the inquiry form. Include airflow, pressure, voltage, application, and quantity. Our engineers will review and provide a detailed quotation within 24 hours.

Request a Quote Request a Technical Proposal Download Catalog

Related Products

HTFC Cabinet Centrifugal Fan Box - related product by Keruite

HTFC Cabinet Centrifugal Fan Box

Low-noise cabinet fan for fire exhaust

View Details
XPZ-I Fire Exhaust Fan - related product by Keruite

XPZ-I Fire Exhaust Fan

Axial fire exhaust fan for high-rise buildings

View Details
XPZ-III Fire Exhaust Fan - related product by Keruite

XPZ-III Fire Exhaust Fan

Centrifugal fire exhaust fan for high pressure

View Details
XPZ-C Fire Exhaust Fan - related product by Keruite

XPZ-C Fire Exhaust Fan

Compact fire exhaust fan for limited spaces

View Details

Interested in GXF Diagonal Flow Fire Fan?

Send us your specifications โ€” airflow, pressure, voltage, and application โ€” for a tailored quotation within 24 hours.