Opposed multi-blade airflow control damper: a detailed guide

Detailed guide to the manual opposed multi-blade airflow control damper: build, size table, features, classification and the smoke-valve range, covering materials, sealing and best fitment.

Manual opposed-multi-blade damper | manual control damper | airflow control damper | control damper.

In air-conditioning and ventilation ducts, fit this product to set airflow by the blade angle. The manual opposed (single) multi-leaf damper fits square or rectangular ducts. A four-bar linkage from the handle sets the angle of the opposed multi-leaf blades, which improves control.

The airflow control damper fits air-conditioning and ventilation ducts and sets airflow by the blade closure angle. The four-bar linkage from the handle moves the opposed multi-leaf blades. The blades lock at any point in their range, and the wheel turns smoothly for easy adjustment. Manual opposed (single) multi-leaf dampers are made to the listed sizes; non-standard sizes are made to order. Large sizes use a multi-cell inner chamber. The damper fits square or rectangular ducts.

Opposed multi-leaf damper specification table (mm)

Model

A×B

L

Model

A×B

L

Model

A×B

L

Model

A×B

L

1

160×320

160

25

400×630

140

49

800×1400

160

73

1400×2000

170

2

200×320

160

26

500×630

140

50

1000×140

16

74

1600×2000

170

3

250×320

160

27

630×630

140

51

1200×1400

160

75

1800×2000

170

4

320×320

160

28

800×630

140

52

1400×1400

160

76

2000×2000

170

5

800×320

160

29

1000×630

140

53

800×1500

160

77

800×2200

170

6

1000×320

160

30

1250×630

140

54

1000×1500

160

78

1000×2200

170

7

200×400

140

31

1600×630

160

55

1200×1500

160

79

1200×2200

170

8

250×400

140

32

800×800

140

56

1400×1500

160

80

1400×2200

170

9

320×400

140

33

1250×800

140

57

1000×1600

160

81

1600×2200

170

10

400×400

140

34

1600×800

160

58

1200×1600

160

82

1800×2200

170

11

800×400

140

35

2000×800

160

59

1400×1600

160

83

800×2500

170

12

1000×400

140

36

800×1000

140

60

1600×1600

160

84

1000×2500

170

13

1250×400

140

37

1000×1000

140

61

1000×1700

160

85

1200×2500

170

14

200×500

140

38

1250×1000

140

62

1200×1700

160

86

1400×2500

170

15

250×500

140

39

1600×1000

160

63

1400×1700

160

87

1600×2500

170

16

320×500

140

40

2000×1000

160

64

1600×1700

160

88

800×2700

170

17

400×500

140

41

1600×1250

160

65

1200×1800

160

89

1000×2700

170

18

500×500

140

42

2000×1250

160

66

1400×1800

160

90

1200×2700

170

19

800×500

140

43

400×800

140

67

1600×1800

160

91

1400×2700

170

20

1000×500

140

44

630×800

140

68

1800×1800

160

92

800×3000

170

21

1250×500

140

45

630×1000

140

69

1200×1900

160

93

1000×3000

170

22

1600×500

140

46

800×1250

140

70

1400×1900

160

94

1200×3000

170

23

250×630

140

47

1000×1250

140

71

1600×1900

160

95

1400×3000

170

24

320×630

140

48

1200×1250

140

72

1800×1900

160


——


For motorised opposed-multi-blade dampers, length L = 170 mm for all sizes.

Product features:

1. The duct connection size of this damper matches the rectangular duct sizes set by the national ventilation duct standard.

2. The damper blades are opposed. In ventilation, air-conditioning and air-purification systems it works as a control damper and is better than a parallel (unison) blade type.

3. The tight opposed-multi-blade damper works both as control and as a shut-off damper, for systems that need shut-off. Examples: fresh-air and exhaust valves on air-conditioning systems, and primary and secondary return-air valves where both sealing and control are needed.

4. Tests show good air tightness, with relative leakage around 5%, and good control performance.

Scope of application:

Usually fitted on ducts of central air-conditioning ventilation systems, normally open. On a fire, when the duct gas reaches 70°C or 280°C, the damper closes automatically and within a set time meets the fire-resistance stability and integrity requirements, blocking smoke and fire. Various stainless-steel air outlets and ceiling air-conditioning nozzles.

Product classification:

The damper comes in manual and motorised types, and by seal level in tight and standard types. The motorised type adjusts airflow automatically with the control system.

The damper is made of galvanised sheet.

Traditional galvanised dampers join the four corners by welding. The heat of welding melts the zinc layer on the sheet, spoiling the look; some use large angle brackets, which cost more.

In traditional cold-rolled and galvanised dampers, the blade ends use brass bushings, some with none. The friction of the blade shaft against the frame is then high; in a large damper the resistance rises further with divided cells. Without bushings, shaft and frame wear grows, play increases over time and blade sealing drops.

In traditional cold-rolled and galvanised dampers, blades generally have no seal between them; they overlap, leaving high leakage.

In traditional cold-rolled and galvanised dampers, blade ends and the frame also have no seal.

For these reasons our engineers developed a welded-free galvanised tight airflow control damper. Its main features:

1. Galvanised sheet frame, no welding at joints, neat appearance.

2. Blades use a composite build, like tight aluminium-alloy blades. Blade ends ride on bearings, so turning resistance is very low — about one third of a traditional damper.

3. Felt strip seals between blades and between blade and frame give good sealing.

4. Gear drive gives lower resistance than the traditional linkage.

5. This damper beats the aluminium-alloy tight damper: above 1.2 m the aluminium type must divide cells because its gears at both ends have play; 0.5 mm of play across many cells leaves the farthest blade unsealed, opening a gap. Our galvanised damper uses one continuous shaft through the blades, so the blade and shaft move as one and avoid this.

Smoke valve series: function overview

Name

Model

功能代号

Function

Size

形状

常态

Smoke valve

PYF-1

SD

Opens on 24 V DC signal; manual open, manual reset, outputs open signal.

≥200×200

Rectangular

Normally closed

PYF-3

SD

≥φ200

Round

Smoke fire damper

PYFH-2

SFD

Opens on 24 V DC signal; manual open, manual reset, outputs open signal; re-closes at 280°C.

≥320×320

Rectangular

PYFH-6

SFD

≥φ200

Round

Remote smoke valve

PYF-4

BSD

Opens on 24 V DC signal; remote manual open, remote manual reset, outputs open signal.

≥320×320

Rectangular

PYF-8

BSD

≥φ200

Round

Remote smoke fire damper

PYFH-5

BSFD

Opens on 24 V DC signal; remote manual open, remote manual reset, outputs open signal; re-closes at 280°C.

≥320×320

Rectangular

PYFH-7

BSFD

≥φ200

Round

Multi-leaf smoke outlet

PYK-2ⅠPYK-2Ⅱ

SD

Opens on 24 V DC signal; manual open, manual reset, outputs open signal.

≥250×250

Rectangular

Multi-leaf fire smoke outlet

PYK-5ⅠPYK-5Ⅱ

SFD

Opens on 24 V DC signal; manual open, manual reset, outputs open signal; re-closes at 280°C.

≥250×250

Rectangular

远控Multi-leaf smoke outlet

PYK-3ⅠPYK-3Ⅱ

BSD

Opens on 24 V DC signal; remote manual open, remote manual reset, outputs open signal.

≥250×250

Rectangular

Remote multi-leaf fire smoke outlet

PYK-4ⅠPYK-4Ⅱ

BSFD

Opens on 24 V DC signal; remote manual open, remote manual reset, outputs open signal; re-closes at 280°C.

≥250×250

Rectangular

Panel smoke outlet

PYK-1

BSD

Opens on 24 V DC signal; remote manual open, remote manual reset, outputs open signal.

≥320×320 ≤800×800

Rectangular

Smoke window

PYC

BSD

Control centre sends a 24 V DC signal to open; remote manual open and reset.

≥250×250

Rectangular

注:
1、产品Model说明: P-排 Y-烟 F-防 H-火 K-口 C-窗
2、功能代号说明: S-电磁铁动作 V-风量调节 F-熔断器动作 D-手动复位
3、温度熔断器另有70℃、90℃、110℃、150℃供用户选用。
K
KRT Engineering Team
Technical Reviewed by Keruite HVAC Engineering Team